What was found
AT C CHECK, RT WING FIXED LEADING EDGE CUT OUT FOR THE NR 5 SLAT INBD TRACK IS CRACKED. REMOVED SEALS TO GAIN ACCESS TO BACKSIDE OF LEAD EDGE OF WING PER SRM 57-30-4, MADE EXTERNAL DOUBLER PICKED UP EXISTING HOLES 2 EA NEW HLOES ONTO NEW DOUBLER PER SRM 57-30-4. ROUTED CRACK APPROXIMATELY .375 INCH LONG PER SRM 57-30-4, TREATED AND PRIMED NEW DOUBLER AND LEADING EDGE OF WING PER SRM 57-30-4, MATERIAL USED: 6X10 .063 2024T3, N/R 2009.