What was found
AT C CHECK, LW NR 7 SPOILER PANEL CENTER HINGE CASTING OUTBOARD LEG CRACKED AT AFT HOLE. CUT OUT CRACK FROM HINGE CASTING 2 LONG PER SRM 51-10-1, DYE PENETRANT INSPECTED CUTOUT PER MIL 68-66B. NO CRACK NOTED, INSTALLED FILLER AND REINFORCING STRAP AT LEFT WING NR 7 SPOILER O/B UPPER FLANGE PER 99AVHM.054R0-1 USED 2024T3 .125 9X3/. TREATED AND PRIMED PER SRM 51-10-2, SEALED LEADING EDGE WITH PRC AS PER SRM 51-20-4, N/R 1207.