What was found
BS 560 FLOOR BEAM UPPER CHORD HAS FLOOR BEAM REPAIR AND CORROSION FROM LBL 4 TO LBL 14.REMOVED OLD REPAIR AND INSTALLED NEW REPAIR PER SRM 53-10-8 , SUPPORT ANGLE 11 , AND 7 N/R 3885
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 560 FLOOR BEAM UPPER CHORD HAS FLOOR BEAM REPAIR AND CORROSION FROM LBL 4 TO LBL 14.REMOVED OLD REPAIR AND INSTALLED NEW REPAIR PER SRM 53-10-8 , SUPPORT ANGLE 11 , AND 7 N/R 3885