What was found
BS 480 FLOORBEAM CORROSION LOWER SIDE OF UPPER CAP FWD SIDE OF LBL 45. CUT OUT DAMAGED AREA AT STA 480 RBL 35, INSTALLED FLOORBEAM REPAIR FROM RBL 35 TO 65 PER SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.