What was found
AT C CHECK, HORIZONTAL WEB CRACKED AT STA 380 AND STA 386 UNDER ANTENNA PANEL - MOUNTED. CUT OUT DAMAGED AREA PER 51-10-1 1 X 17 AREA ON STA 380 AND 1 X 10 AREA ON STA 386, PERFORMED HFEC INSP PER 727 NDT MANUAL PART 6-51-00-00 FIG 4. NO CRACK INDICATIONS AT EITHER CUTOUT, CLEANED TREATED AND PRIMED AREA PER SRM 51-10-2, INSTALLED REAPIR PARTS PER SRM 51-40-2 AND 51-30-2 USING FILLER .040 2024T3 1 X 22 AND DOUBLER 2024T3 4.5 X 34 N/R 3725.