What was found
AT C CHECK, LWR LT BODY FAIRING AFT OF HYD ACCESS PANEL 3519 DELAMINATED AT LWR I/B END AND ALONG EDGE. ALSO, MISSING TWO FASTENERS. REMOVED LWR LT BODY FAIRING PER SRM 51-30-2, REPLACED MISSING FASTENERS PER SRM 51-30-2, INSTALLED FG OVERLAY REPAIR AS PER SRM 51-40-8 FIG 1 USING RESIN 50-A HARDENER 946 7781 CLOTH 25 X 10. INSTALLED LT BODY FAIRNING 3519 PER SRM 51-30-2 N/R 5841.