AT C-CHECK, STA 328 FLOORBEAM AT LBL 46 HAS FLOOR PANEL SCREW HOLE REWORKED BEYOND LIMITS. CUT OUT 3 PIECE OF FLOORBEAM, INSTALLED REPAIR PARTS PER SRM 53-10-8, 19 X 2 ANGLE 27 X 2.25 N/R 5810.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, STA 328 FLOORBEAM AT LBL 46 HAS FLOOR PANEL SCREW HOLE REWORKED BEYOND LIMITS. CUT OUT 3 PIECE OF FLOORBEAM, INSTALLED REPAIR PARTS PER SRM 53-10-8, 19 X 2 ANGLE 27 X 2.25 N/R 5810.