What was found
AT C CHECK, NR 5 SLAT AERODYNAMIC FENCE LEADING EDGE METAL SHIELD DELAMINATING. INSTALLED BONDING REPAIR PER SRM 51-20-3, 6 BY 3, N/R 2029.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CHECK, NR 5 SLAT AERODYNAMIC FENCE LEADING EDGE METAL SHIELD DELAMINATING. INSTALLED BONDING REPAIR PER SRM 51-20-3, 6 BY 3, N/R 2029.