What was found
AT C CHECK, NR 1 SLAT LEADING EDGE EXTERIOR HAS FILLER MATERIAL IN DENTS. REMOVED DAMAGED AREA AND INSTALLED DOUBLER REPAIR PER SRM 57-30-3, 8 BY 4.5, N/R 1351.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CHECK, NR 1 SLAT LEADING EDGE EXTERIOR HAS FILLER MATERIAL IN DENTS. REMOVED DAMAGED AREA AND INSTALLED DOUBLER REPAIR PER SRM 57-30-3, 8 BY 4.5, N/R 1351.