What was found
AT C CHECK, FUSELAGE FRAME DENTED AT BS 720 ABOVE STR 17R. CUT OUT DAMAGED AREA, INSTALLED DOUBLER REPAIR PER SRM 51-40-3, 7 BY 4.75, N/R 5745.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CHECK, FUSELAGE FRAME DENTED AT BS 720 ABOVE STR 17R. CUT OUT DAMAGED AREA, INSTALLED DOUBLER REPAIR PER SRM 51-40-3, 7 BY 4.75, N/R 5745.