What was found
AT C CHECK, FUSELAGE FRAME BS 520 IS DAMAGED AT STR 17R. STOP DRILLED AREA, HFEC, INSTALLED DOUBLER PER SRM 51-40-3, 7 BY 6, N/R 3449.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CHECK, FUSELAGE FRAME BS 520 IS DAMAGED AT STR 17R. STOP DRILLED AREA, HFEC, INSTALLED DOUBLER PER SRM 51-40-3, 7 BY 6, N/R 3449.