What was found
AT C-CHECK, AFT CARGO COMPT LT FLOORING PANELS SHOWS MISSING STRAPS STA 980 TO 1180. FABRICATED STRAP AND INSTALLED PER SRM 51-1-4, 193 X 1.25.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, AFT CARGO COMPT LT FLOORING PANELS SHOWS MISSING STRAPS STA 980 TO 1180. FABRICATED STRAP AND INSTALLED PER SRM 51-1-4, 193 X 1.25.