What was found
AT C-CHECK, RT WING I/B TRAILING EDGE AREA AT STA XWS 5 CRACK ON WEB PANEL JUST ABOVE I/B FLAP I/B HINGE AREA. REMOVED CRACKED PANEL, FABRICATED NEW WEB PER SRM 51-1-21, 15 X 5.5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, RT WING I/B TRAILING EDGE AREA AT STA XWS 5 CRACK ON WEB PANEL JUST ABOVE I/B FLAP I/B HINGE AREA. REMOVED CRACKED PANEL, FABRICATED NEW WEB PER SRM 51-1-21, 15 X 5.5.