AT C CHECK, CENTER WING TANK, THROUGH LOWER ACCESS PANEL 516A RT SIDE BAY ON STA 46 STR 67 UPPER AREA CRACK ON FITTING APPROX 1 LONG. REMOVED AND FABRICATED FITTING PER DER DRAWING MHA 3123 AND INSTALLED PER SRM 51-120D. N/R 1234