What was found
AT C CHECK, NR3 ENG I/B T/R FAN COWL FWD MATING FLANGE HAS CRACK AT 12 O'CLOCK. CUT OUT DAMAGED AREA. FABRICATED REAPIR ANGLE 3.5 BY 3.5 FT AND FILLER 3 BY 1.5 PER EO18R78310191. N/R 1160.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C CHECK, NR3 ENG I/B T/R FAN COWL FWD MATING FLANGE HAS CRACK AT 12 O'CLOCK. CUT OUT DAMAGED AREA. FABRICATED REAPIR ANGLE 3.5 BY 3.5 FT AND FILLER 3 BY 1.5 PER EO18R78310191. N/R 1160.