What was found
NR 1 STRUT OVERHEAT LIGHT AFTER T/O PERFORMED NORMAL SHUTDOWN NR 1 ENGINE PER PROCEDURE. FOUND 4 DUCT CONNECTIONS LEAKING ON DUCT FROM PRECOOLER TO THE ENG. REMOVED AND REINSTALLED DUCTS PER 727 M/M 36-00-01 (DUCTS WERE MIS-ALIGNED) ALSO FOUND NR 1 PYLON OVERHEAT LOOP MIS-ROUTED-REROUTED PER 727 M/M 26-14-01. SYS GRND CKS GOOD AFTER 10 MIN AT TAKEOFF PWR PER M/M 36-00-00 AND M/M 26-14-00. OK FOR CONTINUED SERVICE.