What was found
FUSE FRAME AT BS 1090 HAS DOUBLE DRILLED HOLE OVER STR 8R. ACCOMPLISHED FRAME REPAIR BETWEEN STR 7R AND 9R PER EO COO-2-53-379-08 DATED 10/24/2008. REF FAA FORM 8110-3 DATED 11/6/2008 AND EVA B253-00162 FOR REPAIR APPROVAL. DOCUMENTED ON N/R 2-53.