BS 848 FRAME HAS DOUBLE DRILLED AND ELONGATED HOLES BETWEEN STR 2L AND 5L. ACCOMPLISHED FRAME REPAIR AS REQUIRED PER B727 SRM 53-10-4 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 848 FRAME HAS DOUBLE DRILLED AND ELONGATED HOLES BETWEEN STR 2L AND 5L. ACCOMPLISHED FRAME REPAIR AS REQUIRED PER B727 SRM 53-10-4 FIG 1.