BS 1170 FRAME HAS DOUBLE DRILLED HOLES ON INBD FLANGE BETWEEN STR 16L AND 17L. ACCOMPLISHED FRAME REPAIR AS REQUIRED PER B727 SRM 51-40-3 FIG 1.