What was found
RIGHT WING VANE SLOT REPAIR HAS ELONGATED HOLES, STA XOLDO 67.000. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 07-23-09, EVA D857-00263 REV IR DATED 07-13-09, DWG REV 01 ED-4968. REMOVED EXISTING REPAIR IAW SRM 51-1-21, SRM 51-1-20D. PERFORMED HFEC INSPECTION ALONG THE EDGE OF THE CUT OUT IAW NDT SPM 06-10-01-001. NO CRACK NO CORROSION FOUND. ENCLOSED SMN FORM 242-2. FABRICATED FILLER AND INTERNAL DOUBLER AND DOUBLER IAW DWG ED-4968. PERFORMED HFEC INSPECTION OF REPAIR PARTS IAW NDT SPM 06-10-01-001. NO CRACK FOUND. INSTALLED REPAIR PARTS IAW DWG ED-4968, SRM 51-1-21, SRM 51-1-11, SRM 51-1-20D, SRM 51-3-1.