What was found
MAJOR REPAIR. STRUCTURE UNDER C CROSSSLIDE CARGO DOOR FITTING CRACKED ¼, F.S. 1180.000, L-26L TO 27L. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG. 1. REMOVED CRACKED FITTING IAW SRM 51-1-21 AND SRM 51-1-20D. CLEANED, TREATED, & PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-21, SRM 51-1-20D, AND SRM 51-3-1.