What was found
RIGHT WING CTR L/E UPPER FORMER CRACKED 1/2" STA XFS 291.500. REMOVED FASTENERS IAW SRM 51-1-21, SRM 51-1-20D. PERFORMED STOP HOLE AND FABRICATED ANGLE DOUBLER IAW SRM 57-3-3 PG 15, SRM 57-2-0 PG 9-10. CLEANED, TREATED AND PRIMED AREA AND ANGLE DOUBLERS IAW SRM 51-1-8B. INSTALLED ANGLE DOUBLERS IAW SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1.