What was found
REMOVED EXISTING NON STANDARD REPAIR IAW SRM 51-1-21. FABRICATED REPAIR DOUBLER IAW SRM 53-2-0 FIG. 1D SHEET 3, SRM 53-3-3 FIG. 1 ITEM "A" SRM 51-9-0 FIG 68A. CLEANED, TREATED AND PRIMED AREA & REPAIR PARTS IAW SRM 51-1-8B. INSTALLED REPAIR DOUBLER IAW SRM 53-2-0 FIG. 1D SHEET 3, SRM 51-1-11 (PRC) SRM 51-1-21 (INSP CRITERIA : VISUAL METHOD, INITIAL / REPETITIVE INSP: