What was found
NR 1 ENG PYLON LT UPPER ANGLE CRACKED .7500" STA YN 202.6. PERFORMED MAJOR REPAIR IAW FORM 8110-3 DATED 06-10-10, EVA D854-00335 REV IR DATED 05-13-10. REMOVED FASTENERS IAW SRM 51-1-21, SRM 51-1-20D. CUT OUT DAMAGED AREA IAW SMN DWG ED-5130 REV 01 DATED 05-07-10. NDT INSPECTED CUT OUT AREA IAW NDT SPM PART 06-10-01-001 AND PERFORMED DETAILED VISUAL INSP AROUND AREA IAW SPM PART 09-00-06 FIG 1. NO CRACK NO CORROSION NOR LOOSE FASTENERS FOUND. ENCLOSED SMN FORM 242-2, SMN 242. FABRICATED REPAIR ANGLE AND FILLER IAW SMN DWG ED-5130. HEAT TREATED REPAIR PARTS IAW SRM 51-1-1 PG 1-13-17. ENCLOSED SMN FORM 075. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B, DPS 9.45. INSTALLED REPAIR PARTS IAW SMN DWG ED-5130, SRM 51-1-11 SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1.