What was found
REMOVED AND REPLACED EXISTING REPAIR LOCATED ON RT HORZ STABILIZER AT XE 159.000 UTILIZING APPROVED DATA (REF REPAIR REPORT HS002) PERFORMED MAJOR REPAIR IAW SRM 55-3-1, FIG 1, SHEET 1-2. REMOVED DAMAGED PANEL PLATING IAW SRM 55-1-0 PG 1, SRM 51-1-21. FABRICATED PLATING AND DOUBLER BOTH FROM (A;7075T6 0.025") IAW SRM 55-3-1, FIG 1, SHEET 1-2 ITEM "S" "T". BONDED BOTH PARTS AND EXISTING BEADED PLATING ITEM "R" WITH HYSOL IAW SRM 51-1-9 TR 51-142, SRM 51-1-9A TR 51-141, DPS 1.950 REV "AR". CLEANED, TREATED AND PRIMED AREA + NEW PANEL PLATING INNER FACE IAW SRM 51-1-8B. INSTALLED NEW PANEL PLATING IAW SRM 51-1-11 (PRC) SRM 51-1-21.