What was found
R & R EXISTING REPAIR ON RT RUDDER PLATING AT ZR 61.156 UTILIZING APPROVED DATA. PERFORMED MAJOR REPAIR IAW SRM 55-6-1 FIG. 1. REMOVED PLATING AND EXISTING NON STANDARD REPAIR IAW SRM 55-1-0 PG 1, SRM 51-1-21. FABRICATED NEW PLATING IAW SRM 55-6-1 FIG 1 ITEM "C". CLEANED, TREATED AND PRIMED AREA & NEW PLATING IAW SRM 51-1-8B. INSTALLED NEW PLATING IAW SRM 51-1-11 SRM 51-1-21. REFER TO NR 265718 FOR BALANCING.