What was found
INSPECTED EXISTING REPAIR LOCATED AT FS 1890.000, L36 FOR CONDITION, SECURITY AND CONFORMITY. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3, DATED 12-09-10 AND EVA D853-00384 REV "IR" DATED 11-18-10. REMOVED EXISTING REPAIR IAW SRM 51-1-21. TRIMMED OUT DAMAGED AREA AND FABRICATED 2EA SEGMENTS OF WEB 2EA REPAIR SPLICES IAW DWG ED-5290 DATED 11-12-10. PERFORMED DETAILED VISUAL INSP AROUND WORK AREA. PERFORMED NDT INSP TO TRIMMED OUT AREA AND FABRICATED REPAIR PARTS IAW NDT SPM PART 09 AND NDT SPM PART 06-10-01-001. NO CRACK NOR CORROSION FOUND. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B AND DPS 4.50-36. INSTALLED REPAIR PARTS IAW SMN DWG ED-5290, SRM 51-1-11, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1.