What was found
FWD ACCY COMPT FITTING CORRODED BY EXFOLIATION STA 8.000 L33R. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1 REMOVED CORROSION IAW SRM 51-1-8 PG 17-18 FOUND WITHIN LIMITS IAW SRM 53-2-0, PG 2P. REMOVED CORRODED FITING IAW SRM 51-1-20 D SRM 51-3-0. CLEANED TREATED & PRIMED AREA IAW SRM 51-1-8B INSTALLED NEW FITING IAW SRM 51-3-0, SRM 51-1-20D, SRM 51-3-1.