IN FLIGHT, CREW REPORTED LOSS OF HYD FLUID. ACFT DIVERTED AND LANDED SAFELY. MX FOUND FLUID LEAKING FROM A FAILED O-RING ON THE HYD SYS 'A' PRESSURE SWITCH. THE O-RING AND PRESSURE SWITCH WERE REPLACED.