What was found
A STATIC DISCHARGE DURING DESCENT THAT DISABLED SEVERAL ACFT SYSTEMS. DECLARED AN EMERGENCY. COMPLIED WITH A LIGHTNING STRIKE INSPECTION WITH NO DAMAGE FOUND. THE NR 2 GIA WAS FOUND TO BE INOPERATIVE & WAS REPLACED. GIA CONFIGURATION UPLOAD & OPS CHECKED GOOD & THE ACFT RETURNED TO SERVICE.