What was found
EMERGENCY EXIT SIGN AT 1L DOOR AND EMERGENCY LIGHT F/C RT SIDE OVERHEAD STAYS ON WHEN EMERGENCY TEST SWITCH IS DEPRESSED AT 1L DOOR WILL NOT GO OUT. REPLACED POWER SUPPLY AT 1L DOOR BITE TEST AND OPS CK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT SIGN AT 1L DOOR AND EMERGENCY LIGHT F/C RT SIDE OVERHEAD STAYS ON WHEN EMERGENCY TEST SWITCH IS DEPRESSED AT 1L DOOR WILL NOT GO OUT. REPLACED POWER SUPPLY AT 1L DOOR BITE TEST AND OPS CK GOOD.