What was found
UPON REMOVAL OF TIME-LIMITED REPAIR AT HMV, ADDITIONAL DAMAGE HAS BEEN DICOVERED. STRINGER 28R AT STATION 1050 HAS EXTENSIVE CORROSION AND WILL REQUIRE INSTALLATION OF A SPLICE SECTION. ADDITIONAL CORROSION DAMAGE IS LOCATED APPROXIMATELY 2 INCHES INBOARD AND 2 INCHES FORWARD OF THE EXIST, IN CUTOUT. THE RESULTING CUTOUT IS 4 INCHES BY 5 INCHES BY 0.050 AND LOCATED APPROXIMATELY 15 INCHES AFT OF THE ORIGINAL DAMAGE LOCATION.