What was found
AT HMV2, FOUND NR 2 L/E SLAT, RIB TEMP REPAIR STOP DRILLED CRACK, I/B SIDE OF ACT FITTING. STOP DRILLED CRACK PER MM 57-54-0 FIG 804, FAB'D DOUBLER PER SAME, INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT HMV2, FOUND NR 2 L/E SLAT, RIB TEMP REPAIR STOP DRILLED CRACK, I/B SIDE OF ACT FITTING. STOP DRILLED CRACK PER MM 57-54-0 FIG 804, FAB'D DOUBLER PER SAME, INSTALLED.