What was found
AT HMV THE 5 SLAT LEADING EDGE WAS FOUND WORN AT FENCE. DRILLED REPAIR DOUBLER PER MM 57-54-0. DYE PEN INSP AREA UNDER FENCE FOUND 2 CRACKS STOP DRILLED. INSTALLED DOUBLER PER MM 57-54-0 FIG 817.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.