What was found
DURING OVERHAUL OF THE I/B FLAP, I/B TRACK, SEVERAL AREAS EXCEEDED APPROVED LIMITS FOR WEAR. AREAS INCLUDED MLG BEAM ATTACH BOLT HOLES, NOTCHES, AND SPOTFACES, THE SPOILER BEAM ATTACH BOLT HOLES, THE MLG DOOR FWD AND AFT HINGE FITTING HOLES, THE SPLICE PLATE ATTACH HOLES, THE FWD ATTACH LUG BORES AND FACES, THE TOGGLE DETENT HOLE, THE CLIP ASSEMBLY ATTACH HOLES, AND THE SPACER BAR ATTACH BOLT HOLES REPAIR PER ER/A 387544-14AD AND BF GOODRICH ENGINEERING REPORT 23-0684.