What was found
NR 6 SLAT, ITEM NR 1, INNER CLOSE OUT PANEL LOWER ATTACH ANGLE HAS ELONGATED HOLE 4.5 INCHES FROM I/B END. ITEM NR 2, REPAIR INSUFFICIENT AT LOWER ATTACH ANGLE T-DUCT CUTOUT. REPAIRED BOTH ITEMS PER SRM 57-54-0 FIG 805A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 6 SLAT, ITEM NR 1, INNER CLOSE OUT PANEL LOWER ATTACH ANGLE HAS ELONGATED HOLE 4.5 INCHES FROM I/B END. ITEM NR 2, REPAIR INSUFFICIENT AT LOWER ATTACH ANGLE T-DUCT CUTOUT. REPAIRED BOTH ITEMS PER SRM 57-54-0 FIG 805A.