What was found
DURING INSPECTION, CORROSION WAS FOUND ON THE FUSELAGE SKIN AT STA 870 AND STR 9R. THE CUT OUT MEASURES 5 INCHES BY 3 INCHES, IN ACCORDANCE WITH B727 SRM 53-30-3 FIG 3A, A DOUBLER AND TRIPLER WERE INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, CORROSION WAS FOUND ON THE FUSELAGE SKIN AT STA 870 AND STR 9R. THE CUT OUT MEASURES 5 INCHES BY 3 INCHES, IN ACCORDANCE WITH B727 SRM 53-30-3 FIG 3A, A DOUBLER AND TRIPLER WERE INSTALLED.