What was found
FLOOR MOUNTED EMERGENCY LIGHT INOP IN FIRST CLASS. FOUND WIRE W1026-9006 SHORTED TO GROUND BETWEEN C/P D9059P AND DISCONNECT D9062. REPLACED WIRE. REPLACED POWER SUPPLY M9026 AND BATTERY PACK. SYSTEM TESTS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR MOUNTED EMERGENCY LIGHT INOP IN FIRST CLASS. FOUND WIRE W1026-9006 SHORTED TO GROUND BETWEEN C/P D9059P AND DISCONNECT D9062. REPLACED WIRE. REPLACED POWER SUPPLY M9026 AND BATTERY PACK. SYSTEM TESTS GOOD.