What was found
INSPECTION OF THE WL 283 FASTENER HOLES ON THE RBL & LBL 17.8 BEAMS OF THE FS 1183 BULKHEAD REVEALED TOOLING DAMAGE IN THE TWO RT HOLES AND A CRACK INDICATION IN THE LOWER LT HOLE. THE INSPECTION WAS ACCOMPLISHED PER AD 99-18-05 AND BAC S/B 727-53-0210. THE TOOLING DAMAGE HOLES WERE REAMED TO CLEAN UP THE DAMAGE AND THE CRACKED HOLE OVERSIZED WITH AN INSURANCE CUT. LARGER DIA BOLTS WERE INSTALLED PER ER/A.