What was found
FUSELAGE / VENTRAL STAIRWAY / RH TORQUE BOX STRUCTURE / FS 1263 : CRACK REPAIR THE VENTRAL STAIRWAY ACTUATOR ON THE RH TORQUE BOX AT FS 1263 WAS FOUND PULLED THROUGH THE UPPER WEB OF THE TORQUE BOX, RESULTING IN CRACKING DAMAGE TO THE UPPER WEB, SIDE WEB, AND UNDERLYING STIFFENERS. THE DAMAGE TO THE UPPER WEB WAS REMOVED WITH A CUTOUT AND REPAIRED WITH AN ALUMINUM DOUBLER. ALL OTHER MEMBERS REPLACED. THE REPAIR WAS ACCOMPLISHED PER ER/A 384097-14AD.