What was found
AFTER T/O AMBER LED LIGHT REMAINED ILLUMINATED AT FLAPS 2. POSITION TEST SHOWED NR 4 L/E DEVICE NOT RETRACTED. REPLACED NR 4 SLAT ACTUATOR.