What was found
CLIMBING THROUGH FL 320, HAD VISIBLE SMOKE AND FUMES COMING FROM CONDUIT BETWEEN R-2 AND R-3 COCKPIT WINDOWS ON F/O SIDE. SMOKE CLEARED WHEN WINDOW HEAT TURNED OFF. REPLACED R-2 WINDOW AND CONTROLLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLIMBING THROUGH FL 320, HAD VISIBLE SMOKE AND FUMES COMING FROM CONDUIT BETWEEN R-2 AND R-3 COCKPIT WINDOWS ON F/O SIDE. SMOKE CLEARED WHEN WINDOW HEAT TURNED OFF. REPLACED R-2 WINDOW AND CONTROLLER.