What was found
DURING LETTER CHECK INSPECTION, THE RT TORQUE BOX UPPER TRANSVERSE BEAM CHANNEL AT FS 1263 WAS FOUND CRACKED. IN ACCORDANCE WITH BAC S/B 727-53-0129 REV 4, THE CHANNEL WAS REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING LETTER CHECK INSPECTION, THE RT TORQUE BOX UPPER TRANSVERSE BEAM CHANNEL AT FS 1263 WAS FOUND CRACKED. IN ACCORDANCE WITH BAC S/B 727-53-0129 REV 4, THE CHANNEL WAS REPLACED.