What was found
TOP OF VERT U-SUPPORT CHANNELS, UNDER CABIN FLOOR, ARE WORN AT TOP AND ATTACH BOLT WASHERS AT RBL 24 AND 52 STA 720D AND 24 LBL. SUPPORTS CAME FROM B/B. INSTALLED PER SRM 53-10-9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TOP OF VERT U-SUPPORT CHANNELS, UNDER CABIN FLOOR, ARE WORN AT TOP AND ATTACH BOLT WASHERS AT RBL 24 AND 52 STA 720D AND 24 LBL. SUPPORTS CAME FROM B/B. INSTALLED PER SRM 53-10-9.