What was found
NR 6 SLAT RIB CRACKED ON INBD END. MADE DOUBLER IAW MM. DRILLED UP AND TREATED AND PAINTED. INSTALLED DOUBLER PER M/M 57-54-0 FIG 814. INSTALLED SEAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 6 SLAT RIB CRACKED ON INBD END. MADE DOUBLER IAW MM. DRILLED UP AND TREATED AND PAINTED. INSTALLED DOUBLER PER M/M 57-54-0 FIG 814. INSTALLED SEAL.