What was found
WING, RIB, BL 70.5, STA 760.95, UPPER RIB CHORD, REPAIR FOR CRACKED FASTENER HOLES. WHILE ACCOMPLISHING AND MANDATED INSPECTIONS OF THE BL 70.5 RIB CHORD AT STA 760.95, SEVERAL FASTENER HOLES SHOWED CRACK INDICATIONS. THE CRACKED HOLES WERE OVERSIZED TO ELIMINATE THE CRACKS, BUSHED AS REQUIRED, AND A REPAIR INSTALLED SIMILAR TO THE REPAIR IN BAC S/B 727-57-112, REV 5. THE DEVIATIONS TO THE S/B WERE GRANTED AMOC AND DOCUMENTED IN ER/A 363384-14AD, REV A.