What was found
THE FUSELAGE SKIN AT STRINGER 22L BETWEEN FS 1110 AND 1166 WAS TORN AND GOUGED DUE TO CONTACT WITH GROUND EQUIPMENT. THE DAMAGE WAS REMOVED FROM THE SKIN WITH TWO CUTOUTS MEASURING 4 X 28.25 AND 3.25 X 16.5. THE CUTOUTS WERE REPAIRED WITH A SINGLE EXTERNAL ALUMINUM DOUBLER. INSTALLED PER ER/A 365850-14, REV A. A NEW SECTION OF STRINGER WAS SPLICED IN PER THE B727 SRM.