What was found
LFEC INSPECTION OF THE STRINGER 4R SKIN LAP SPLICE BETWEEN FS 360 AND 481 INDICATED CRACKS IN THE LOWER FASTENER ROW OF THE LOWER SKIN PANEL. HFEC INTERNAL INSPECTION CONFIRMED 4 CRACKS IN TWO CONSECUTIVE FRAME BAYS. THE ENTIRE SKIN LAP SPLICE WAS CUTOUT ALONG THE PANEL LENGTH. THE LAP WAS REPAIRED WITH AN EXTERNAL ALUMINUM DOUBLER INSTALLED PER ER/A 366743-14, REV A.