What was found
FRAME DENTED AFT CARGO COMPT RT FRAME DENTED AT STA 950C SEVERAL PLACES FROM STR 25R TO STR 26R. CUT OUT DAMAGE PER SRM 53-10-4 FIG 27. DYE PENETRANT INSPECTED CUTOUT PER PS 900-6-3 NO 1 AND FOUND OK. DRILLED DOUBLER AND FILLER PER SRM 53-10-4 FIG 27 AND TREATED PER PS 900-2-4-1, NR 2. PAINTED PER PS 900-3-6. INSTALLED REPAIR PARTS PER SRM 53-10-4 FIG 27.