What was found
AT HMV, STRINGER 15L WAS FOUND CRACKED AT ITS END AT FS 72OC LEFT WING ICE LIGHT HOUSING. REPAIRED PER SRM 53-10-3 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT HMV, STRINGER 15L WAS FOUND CRACKED AT ITS END AT FS 72OC LEFT WING ICE LIGHT HOUSING. REPAIRED PER SRM 53-10-3 FIG 2.